A nicked electrical wire looks like a small problem — a tiny gouge in the copper conductor from a slipping stripper, a utility knife score, or a pinched cable. In practice, that nick is the origin of every silent wire failure five years from now. Heat concentrates at the defect, insulation weakens, and eventually the conductor breaks or arcs. This guide walks GTA homeowners through how to fix a nicked electrical wire, when the fix works, and when the only correct answer is to cut back and re-strip.
Short answer: cut back and re-strip if possible; otherwise splice with proper connectors
Direct answer: the correct fix for a nicked wire is to cut off the damaged section and re-strip fresh conductor. If insufficient conductor length remains, splice a fresh piece of the same-gauge conductor onto the nicked wire using a marrette inside a listed junction box. Never wrap electrical tape over a nick and leave it as “repaired.”
Why nicks matter more than they look
Reduced current-carrying capacity. A nick reduces the cross-sectional area of the conductor. Current concentrates through the smaller section, generating heat.
Insulation degradation from local heating. Heat at the nick cooks the surrounding insulation, cracking and eventually exposing more copper.
Fatigue failure over time. Thermal expansion and contraction at the nick eventually breaks the conductor completely.
Arc fault risk. Under high load, a nick can arc briefly — the source of many mystery fires attributed to “electrical” causes.
The Electrical Safety Authority lists conductor-defect-related failures among residential incidents in the Ontario Electrical Safety Report. Small nicks compound over decades.
Step-by-step: cut back and re-strip
Kill the breaker feeding the circuit. Verify with a non-contact voltage tester.
Pull the cable back to expose enough conductor for a re-strip. If enough conductor remains (usually 200 mm inside the box), you can re-strip without adding a splice.
Cut off the nicked section with wire strippers or lineman’s pliers. Cut past the nick by at least 20 mm.
When you cannot cut back: splice in a junction box
Install a junction box where the nicked section is accessible. The junction must remain accessible — not buried behind drywall.
Cut the cable at the nick.
Strip both ends with proper technique.
Splice with marrettes. Same-colour conductors together (black to black, white to white, bond to bond).
Install a blank cover plate.
Label the panel schedule to note the junction box location.
Buried splices behind drywall are prohibited under Section 12 of the Ontario Electrical Safety Code. Every splice must remain accessible.
What NOT to do
Do not wrap tape over a nick. Tape does not restore conductor capacity.
Do not solder the nick. Solder introduces its own failure modes; residential wiring does not use solder joints.
Do not bury the repaired section. Splices must be accessible.
Do not skip a proper junction box. Free-hanging marrettes in a wall cavity are code violations.
Do not ignore small nicks. Even a shallow nick propagates over time.
When the whole cable needs replacement
Direct answer: if the nick is in the middle of a long run, if multiple nicks are present, or if the cable has been damaged by chewing, pinching, or heat, replace the entire cable rather than splicing repeatedly. Multiple splices reduce reliability and complicate future troubleshooting.
Wrong-size stripper notch. Using the 12 AWG notch on 14 AWG cuts through the conductor. Use the correct notch.
Utility knife stripping. Always nicks. Use a proper wire stripper.
Pinched cable during device installation. Fold conductors carefully into the box; do not pinch between yoke and box wall.
Fishing damage. Fish tape or rough box entry can nick cable. Use protective bushings and pull carefully.
Rodent damage. Mice chew cable jacket exposed in attics or basements. Fix rodent entry points and inspect exposed cable.
Expert tip from our ESA-licensed electricians
In our experience diagnosing intermittent electrical failures across GTA homes, the most common invisible cause is a nick that happened during the original install decades ago. The device worked fine at inspection; the nicked conductor slowly degraded over 20-30 years until it finally failed. When we cut back and re-terminate, the failure disappears. Homeowners doing their own work can avoid the same trap by using a proper wire stripper with sized notches (see our post on cutting and stripping) and inspecting exposed copper under good light before terminating. Ten seconds of inspection saves a service call in 2050. Same lesson as the torque driver, the multimeter, and the tester battery check — pre-emptive habits eliminate the failure modes that show up years later.
Nicked conductor in a GTA home that needs a proper repair? Book an ESA-certified electrician. Call us at 416-838-9006 or visit our contact page — we will get back to you the same day.
Used to monitor number of Google Analytics server requests
10 minutes
__utmb
Used to distinguish new sessions and visits. This cookie is set when the GA.js javascript library is loaded and there is no existing __utmb cookie. The cookie is updated every time data is sent to the Google Analytics server.
30 minutes after last activity
__utmc
Used only with old Urchin versions of Google Analytics and not with GA.js. Was used to distinguish between new sessions and visits at the end of a session.
End of session (browser)
__utmz
Contains information about the traffic source or campaign that directed user to the website. The cookie is set when the GA.js javascript is loaded and updated when data is sent to the Google Anaytics server
6 months after last activity
__utmv
Contains custom information set by the web developer via the _setCustomVar method in Google Analytics. This cookie is updated every time new data is sent to the Google Analytics server.
2 years after last activity
__utmx
Used to determine whether a user is included in an A / B or Multivariate test.
18 months
_ga
ID used to identify users
2 years
_gali
Used by Google Analytics to determine which links on a page are being clicked
30 seconds
_ga_
ID used to identify users
2 years
_gid
ID used to identify users for 24 hours after last activity
24 hours
_gat
Used to monitor number of Google Analytics server requests when using Google Tag Manager
1 minute
_gac_
Contains information related to marketing campaigns of the user. These are shared with Google AdWords / Google Ads when the Google Ads and Google Analytics accounts are linked together.
90 days
SourceBuster is used by WooCommerce for order attribution based on user source.
Name
Description
Duration
sbjs_session
The number of page views in this session and the current page path
30 minutes
sbjs_udata
Information about the visitor’s user agent, such as IP, the browser, and the device type
session
sbjs_first
Traffic origin information for the visitor’s first visit to your store (only applicable if the visitor returns before the session expires)
session
sbjs_current
Traffic origin information for the visitor’s current visit to your store
session
sbjs_first_add
Timestamp, referring URL, and entry page for your visitor’s first visit to your store (only applicable if the visitor returns before the session expires)
session
sbjs_current_add
Timestamp, referring URL, and entry page for your visitor’s current visit to your store
session
sbjs_migrations
Technical data to help with migrations between different versions of the tracking feature
session
Marketing cookies are used to follow visitors to websites. The intention is to show ads that are relevant and engaging to the individual user.
Google Maps is a web mapping service providing satellite imagery, real-time navigation, and location-based information.