Rodents and electrical wiring are a dangerous combination. Whether rats can get through your conduit depends on the conduit material — and the answer has real consequences for your electrical safety.
Rats have incisors that generate roughly 12 GPa of pressure — comparable to steel hardness. They can chew through soft plastic conduit (PVC, flexible non-metallic conduit) relatively easily. They can also chew through Loomex/NMD-90 cable sheathing and wire insulation. What they cannot reliably penetrate is rigid metal conduit (RMC), electrical metallic tubing (EMT), or galvanized steel flex. The rodent resistance of conduit is entirely a function of whether it’s metallic.
When rats chew insulation off wires, the exposed conductors can contact each other (causing a short circuit or blown breaker) or contact a combustible surface (causing a fire). Rodent-damaged wiring is estimated to cause approximately 25% of house fires with unknown origins in North America. The damage typically occurs inside wall cavities and attics — invisible until a circuit fails or a fire starts. Nesting material packed around chewed wires dramatically increases fire risk because rodents gather paper, fabric, and other flammables near electrical runs.
Intermittent circuit failures, breakers that trip without an apparent load cause, or flickering in a specific area of your home can all indicate chewed wiring. During a pest inspection, look for droppings, gnaw marks, or nesting material near electrical runs in the attic or basement. Any visible wire insulation damage requires immediate attention from a licensed electrician before power is restored to that circuit.
In areas with known rodent activity, run wiring in EMT or RMC instead of NMD-90 or flexible plastic conduit. Seal any entry points around cable penetrations through walls, floors, and ceiling plates — rodents enter through gaps as small as a quarter. If you’ve had an active rodent infestation, have an electrician inspect accessible wiring runs before assuming the system is undamaged.
Attic rewiring after a rodent infestation is one of the more common emergency calls we get in older Toronto neighbourhoods. The pattern is always the same: a pest company removes the rodents, the homeowner notices intermittent circuit issues months later, and by the time we get in the attic there are chewed wires throughout the insulation. If you’ve had a confirmed rodent infestation in an attic or wall cavity that contains wiring, budget for an electrical inspection — it’s not optional.
Suspect rodent damage to your home’s wiring? Call us at 416-838-9006 or visit our contact page — we inspect and repair rodent-damaged electrical systems across the GTA.
Electrician Since 2008 Journeyman Electrician Designated Master Electrician at EZSMART Corp