What Is the Color Code for House Wiring?

Open any electrical box in a Canadian home and you see the same colour palette — black, white, red, green, and bare copper. Each colour carries a specific meaning under the Ontario Electrical Safety Code, and mixing them up is the fastest way to create a shock hazard or a code violation. This guide walks GTA homeowners through the colour code for house wiring, what each colour signifies in Canadian residential installations, and where the code allows re-marking for special cases.

Short answer: black hot, white neutral, red second hot, green or bare bond

Direct answer: in Canadian residential wiring following the Ontario Electrical Safety Code, black is the primary hot conductor, white is neutral (grounded conductor), red is a second hot in 14/3 or 12/3 cable, green is an insulated equipment bond, and bare copper is a non-insulated equipment bond. These colours are consistent across NMD-90 cable used throughout Ontario.

What each colour means

  • Black: hot (energized) conductor. The primary line-side conductor bringing 120 V from the panel.
  • White: neutral (grounded conductor). The return conductor to the panel at 0 V under normal conditions. Never used as a switched hot except when re-marked (see below).
  • Red: second hot conductor in 14/3 or 12/3 cable. Used for 3-way switches, split receptacles, and 240 V circuits.
  • Green: insulated equipment bond (safety ground). Only carries current under fault conditions.
  • Bare copper: non-insulated equipment bond. Common in NMD-90 cable.
  • Blue, yellow, or brown: less common; sometimes used in three-phase installations or specific commercial systems.

When white is used as a hot conductor

Direct answer: in some legacy switch-loop configurations, the white conductor in a 14/2 cable functioned as a switched hot from the ceiling box down to the switch. The Ontario Electrical Safety Code allows this only if the white conductor is re-marked at both ends with black tape or black paint (three inch minimum wrap) to visually identify it as a hot.

Modern installations use 14/3 cable to avoid the white-as-hot issue. Older homes may still have this configuration — respect the re-marking convention and do not assume white is neutral if it is on a hot terminal.

Canadian vs US colour code differences

Direct answer: US NEC and Canadian OESC largely agree on residential 120 V colours (black, white, green, bare). Differences appear in commercial and industrial three-phase installations, where colour codes can vary by jurisdiction. Residential DIY in Ontario follows the Canadian standard consistently.

Our post on Romex vs THHN vs UF covers cable types where different colour conventions can appear.

What NOT to do with colours

  • Do not tie neutral (white) to hot (black) at any point. Creates a short circuit.
  • Do not use bond (bare or green) to carry current under normal conditions. Bond is only for fault current.
  • Do not use unmarked white as a hot in modern installations. Use 14/3 cable with a red conductor instead.
  • Do not re-purpose colours without re-marking. A white conductor used as a hot must be wrapped with black tape at both ends.
  • Do not connect device screws to the wrong colour. Black to brass; white to silver; green/bare to green screw.

Device terminal colour convention

  • Brass screw: hot connection (black or red conductor).
  • Silver screw: neutral connection (white conductor).
  • Green screw: equipment bond (green or bare conductor).
  • Push-in “backstab”: spring-loaded terminal on some devices — avoid using in favour of side screws (see our post on tightening screw terminals).

What to do if you find non-standard colours

Direct answer: if you open a box and find conductors that do not match the standard code (all-white, all-black, or unusual combinations like yellow or blue), stop and consult a licensed electrician. Old installations, DIY modifications, or non-Canadian cable can create confusing conditions where the code no longer applies at face value.

The Electrical Safety Authority notes that miswired devices from incorrect colour assumptions are among the top homeowner-caused writeups on residential inspections. When in doubt, use a multimeter to verify voltage before touching anything.

Expert tip from our ESA-licensed electricians

In our experience diagnosing GTA wiring across all vintages of Ontario homes, the single most common colour-related mistake is assuming white is always neutral. In 14/2 switch loops installed before about 2000, the white conductor between the ceiling box and the wall switch is a switched hot. If the previous owner did not re-mark it with black tape, the next homeowner opens the box and assumes the white is safe to touch. Our rule: verify every conductor with a multimeter before terminating, regardless of colour. Colours are a guide, not a guarantee. Our post on multimeter use covers the verification technique.

Frequently Asked Questions

What are the standard Canadian house wiring colours?

Black = hot, white = neutral, bare copper (or green) = ground, red = second hot or switched hot.

Do all cables follow the same colours?

Modern NMD90 does. Older cloth-insulated cable used different or faded colours — verify with a meter.

What does a re-identified white wire mean?

White taped or marked black at both ends indicates it is being used as a hot in a switch loop.

Are there special colours for 240V circuits?

Two hots (black and red typically) plus neutral (white) and ground. No special colour just for 240V.

What if I find a mystery colour?

Do not guess. Meter the conductor and, if in doubt, call a licensed electrician.

Contact us

Found unusual colours in a GTA electrical box and unsure how to interpret them? Book an ESA-certified electrician. Call us at 416-838-9006 or visit our contact page — we will get back to you the same day.

Amir Azimipour

Electrician Since 2008 Journeyman Electrician Designated Master Electrician at EZSMART Corp

Recent Comments

No comments to show.

Archive

September 2026
MTWTFSS
 123456
78910111213
14151617181920
21222324252627
282930 

Recent Posts

12 Sep, 2026

Is It Safe to Do DIY Electrical Work Without Shutting Off the Main?

Is It Safe to Do DIY Electrical Work Without Shutting Off the Main? Wo

07 Sep, 2026

Can Solar Panels Completely Power a House in Ontario?

Can Solar Panels Completely Power a House in Ontario? Solar panels can

Click to chat with us
Chat with us