The distance between an electrical outlet and a kitchen sink is governed by the Ontario Electrical Safety Code (OESC) and enforced on every kitchen renovation or new construction. The rules are specific, measurable, and non-negotiable.
In Ontario, any outlet within 1.5 metres (approximately 5 feet) of a kitchen sink must be protected by a Ground Fault Circuit Interrupter (GFCI). Additionally, countertop outlets must be spaced so no point along the countertop is more than 900mm (about 3 feet) from a receptacle.
Any receptacle within 1.5 metres of a kitchen sink must be GFCI-protected. This applies whether the outlet is on the countertop, on the wall above the countertop, or in a nearby island. A GFCI breaker in the panel can also satisfy the requirement for an entire circuit.
Kitchen countertop outlets must be spaced so that no point on any countertop section is more than 900mm from a receptacle. This prevents the use of extension cords across countertop surfaces. Each separate countertop section must meet the 900mm rule independently.