What Is Armor-Clad (BX) Cable?

BX cable — conductors wrapped in a flexible metal spiral jacket instead of the plastic sheath on standard NMD90 — shows up in a lot of Toronto and GTA homes, both as older original wiring and as a modern cable type still used for specific applications today. Unlike knob-and-tube or cloth wiring, finding BX cable is not automatically a red flag. This guide covers what it actually is and when it matters.

What is armor-clad (BX) cable?

BX cable (the trade name; the current Canadian designation is AC90, for Armored Cable rated 90°C) consists of insulated conductors wrapped in a flexible, spiral-wound metal sheath. The metal jacket provides mechanical protection the plastic sheath on NMD90 does not, which is why AC90 remains a code-recognized, actively used cable type today — not a deprecated legacy product like knob-and-tube. Whether existing BX wiring in an older home is a concern depends entirely on its age, condition, and how the metal jacket itself is functioning as the ground path, which is where older BX installations sometimes fall short of current standards.

Where AC90/BX is still used today

  • Exposed locations where mechanical protection matters, like a garage or basement wall without drywall covering.
  • Commercial and some multi-unit residential construction, where it is a common standard.
  • Short connections to equipment that needs flexibility plus protection, similar in application to how liquid-tight flexible conduit is used.
  • Renovations matching existing armored cable runs for consistency with the original installation.

It is genuinely different from NMD90 in application, not a worse or outdated version of it — see what is the difference between NM cable and armored cable for the fuller comparison.

The specific concern with OLDER BX cable

The issue in a Toronto or GTA home is not the metal jacket itself — it is how grounding was handled on older installations. Modern AC90 cable includes a dedicated bonding conductor inside the jacket specifically for grounding. Older BX cable sometimes relied on the metal armor itself as the ground path, with continuity depending on tight, clean connections at every single connector and box along the run. Over decades, those connections can loosen or corrode, degrading the ground path’s reliability in a way that is not visible from outside — the same invisible-until-tested problem covered in what are the signs of a bad ground wire.

How to tell if your BX is old-style armor-ground or modern with a bonding wire

  • A licensed contractor can check at an accessible box whether a dedicated bare or green bonding conductor exists inside the armor, separate from the insulated hot and neutral conductors.
  • Age is a rough guide but not definitive — the era of the installation and the specific product used both matter.
  • A continuity test at the panel confirms whether the ground path (armor-only or dedicated conductor) is actually intact end to end, which visual inspection alone cannot fully verify.

Is BX cable in an old home a problem?

Not automatically. Sound BX cable with intact connections and a verified ground path is a legitimate, functioning wiring system, not a defect to be replaced on sight the way active knob-and-tube or crumbling cloth insulation is treated. The practical response is verification, not automatic replacement:

  • Have a licensed contractor confirm ground continuity through the armor (or locate the dedicated bonding conductor if present).
  • Check connector tightness at accessible junction points — loose connectors are a correctable maintenance item, not a reason to rewire.
  • Address any specific circuit that fails the continuity check rather than assuming the whole system needs replacement.

Insurance and resale perspective

BX/AC90 cable does not carry the same blanket insurance concern that knob-and-tube or aluminum branch wiring does in Ontario, because it is still an actively used, code-current cable type rather than a discontinued legacy system. Insurers and home inspectors are generally more interested in the specific condition and grounding verification than the presence of BX cable itself.

Expert tip from our ESA-licensed electricians

The BX calls we get in the GTA usually come from a homeowner who read online that BX cable is dangerous and panicked, when the actual system in their home has been running fine for decades. The real question is never “do I have BX cable” — it is “does the ground path through this specific run test as continuous and low-resistance.” That is a fifteen-minute check with a meter, not a rewrite of the whole electrical system. Get the continuity verified before assuming the cable itself is the problem.

Frequently Asked Questions

Is BX cable the same as knob and tube?

No. Knob and tube is discontinued open-air wiring from an earlier era. BX/AC90 is a metal-jacketed cable type still actively used in current construction.

Does old BX cable need to be replaced?

Not automatically — verify the ground path integrity first. Sound BX with confirmed continuity is a legitimate wiring system.

How does the ground work in BX cable?

Modern AC90 includes a dedicated bonding conductor. Older BX sometimes relies on the metal armor itself, which depends on tight connections throughout.

Can I still buy BX/AC90 cable today?

Yes, it remains a current, code-recognized product used for specific applications where mechanical protection matters.

Does insurance treat BX cable like knob-and-tube?

Generally no, since it is an actively used current cable type rather than a discontinued legacy system.

Contact us

Found BX cable in your Toronto or GTA home and want the ground path verified? Call ezsmart at 416-838-9006 or use our contact page. An ESA-licensed electrician will test it properly.

Amir Azimipour

Electrician Since 2008 Journeyman Electrician Designated Master Electrician at EZSMART Corp

Recent Comments

No comments to show.

Archive

August 2026
M T W T F S S
 12
3456789
10111213141516
17181920212223
24252627282930
31  

Recent Posts

02 Aug, 2026

How Do You Find a Broken Wire Underground?

In this articleHow do you find a broken wire underground?Step 1: confi

08 Jul, 2026

Why Does My Breaker Keep Tripping?

A breaker that trips once in a while is usually nothing to worry about

Chat with us